Lexa sterilizer

High capacity and efficiency

Lexa offers versatile cycle program options for medium and larger loads, guaranteed by the closed-door drying process with HEPA filters and the use of fresh water for each cycle.

  • Lara incredible outside

    Sterilization on a high standard

    Built to offer more of all that counts in every day medical infection control.

    Your sterilization process deserves Lexa!

    • Increased efficiency due to the large chamber capacity and short cycle times, including excellent load drying.
    • Increased flexibility due to the userfriendly tray and exclusive rack design.
    • Increased usability due to the simple and intuitive menu interface, high-end color touchdisplay and ergonomic design.
    • Increased protection due to a complete and customizable traceability system.

    8 kg (18 lbs) sterilized and dried in 30 minutes!

    Higher efficiency due to higher capacity ... Lexa comes with 4 large trays along with a unique rack providing larger loading surface and more loading options.

    ... and less cycle time. Lexa offers versatile program options for medium and larger loads in order to reduce overall cycle duration.

    Your advantages at a glance

    • User-friendly interface and high-end color touchdisplay for simple navigation to all sterilization option
    • Customizable drying time
    • Large capacity sterilizer chamber with unique tray and exclusive design
    • Versatile sterilization program options with short cycle times
    • Superior vacuum-assisted drying
    • Meets stringent hygiene standards, including dynamic pulsed air removal, closed door drying and single-use water management
    • Easy maintenance – Lexa does not require periodic execution of cleaning cycles
    • Programmable cycle start
    • Excellent value for money
    • Automatic digital cycle recording on USB stick
    • User authentication and load release (optional)
    • Barcode label printing (optional)

    Lexa sterilizer

    supplied with reversible rack, 4 aluminium trays, drain tube, tray holder, USB drive, door opening tool, factory test

    Warranty details: 2 years or 2,000 cycles - whichever comes first.

    Lexa MN-111
    110 V

    REF 19943411

    Chamber size 28 l
    100–125 V AC; 50/60 Hz; 12 A Single Phase

    Lexa MN-111
    220 V

    REF 19943111

    Chamber size 28 l
    200–240 V AC; 50/60 Hz 10 A Single Phase

    Download Area

    Videos & Tutorials

    For a seamless and interactive online experience of our multimedia content (e.g. videos, maps), please accept the storage of the necessary cookies (YouTube, MovingImage - detailed information on these cookies can be found in the imprint/data protection) for marketing purposes.

    Accept

  • Lexa sterilization programs

    Sterilization cycle Unwrapped Wrapped Medium Load
    Wrapped Large Load Wrapped X-Large Load Low
    Temperature
    Temperature: 132°C (270°F) 132°C (270°F) 132°C (270°F) 132°C (270°F) 121 °C (250 °F)
    Holding time (minutes): 4’ 4’ 4’ 4’ 4’
    Total cycle duration (minutes) including drying*: 26’–39’ 43’–53’ 48’–58’ 58’–71’ 73’–79’
    Max. load (excluding trays): 8.1 kg (18 lbs) 1.4 kg (3 lbs) 2.7 kg (6 lbs) 6.4 kg (14 lbs) 2.3 & 2 kg (5 & 4.4 lbs) including trays


    Items supplied with: reversible rack, 4 aluminium trays, drain tube, tray holder, USB drive, door opening tool, factory test.


    * Cycle times are approximate and may vary depending on voltage and instrument loads.

    Trade name: Lexa 110 V Lexa 220 V
    Type: MN-111
    Chamber size: 28 l (7.4 gal)
    Power supply: 100–125 V AC; 50/60 Hz; 12 A Single Phase
    200–240 V AC; 50/60 Hz 10 A Single Phase
    Overall dimension
    (width x height x depth):
    490 x 452 x 616 mm (19.3“ x 17.8“ x 24.3“)
    Weight: 48 kg (105.8 lbs)
    Main / Used water tanks: 6.4/6.7 l (1.7/1.8 gal)
    Connection types: 5 USB ports, 1 Ethernet port

    Lexa sterilizers were designed, certified and validated according to the following standards and directives:
    N°2017/745 Medical Device Regulation
    2014/68/EU Pressure Equipment Directive
    EN 13060 Small steam sterilizer
    EN 61326-1 Electromagnetic compatibility
    EN 61010-1 Safety requirements
    EN 61010-2-040 Specific requirements for steam sterilizer
    IEC 61770 Back syphonage
    ASME* Boiler and pressure vessel code
    ANSI/AAMI ST55:2010 Table-top steam sterilizers
    CSA C22.2 No. 61010-1-12 Safety requirements for electrical equipment for measurement, control and laboratory use, general requirements.
    2012/19/EU Waste Electrical and Electronic Equipment (WEEE)
    UL 61010-1:2012 Safety requirements for electrical equipment for measurement, control and laboratory use, general requirements.
    2014/68/EU Pressure equipment Directive


    The sterilizer can be validated according to EN ISO 17665-1

    *On Request